Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Clin Transl Allergy ; 14(4): e12354, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38658181

RESUMEN

BACKGROUND: Chronic rhinosinusitis (CRS) is a chronic inflammatory disease of the nose and paranasal sinuses lasting ≥12 weeks. CRS may exist with (CRSwNP) or without (CRSsNP) nasal polyps. The aim was to evaluate conditions associated with CRS in a randomized hospital cohort. We hypothesized that comorbidities and surgical procedures differ between pediatric and adult patients. METHODS: This study consisted of hospital registry data of a random sample of rhinosinusitis patients (age range 0-89 years) with the diagnosis of J32 or J33, correspondingly, registered during outpatient visits from 2005 to 2019 (n = 1461). The covariates of interest were collected from electronic health records based on ICD-10 codes and keyword searches. RESULTS: Among pediatric patients (n = 104), the relative proportions of CRSsNP and CRSwNP were 86% and 14% respectively. The relative proportions of adult patients (n = 1357) with CRSsNP and CRSwNP were 60% and 40%, respectively. The following comorbidities significantly differed (p < 0.05) between pediatric and adult populations: allergy, chronic otitis media, and tonsillar diseases. In total, 41 % of the children and 46% of the adults underwent baseline endoscopic sinus surgery (ESS). Additional surgeries of the ear, nose and pharynx were significantly more common among children compared with adults. Risk of revision after baseline ESS was associated (p < 0.05) with allergy, asthma, eosinophilia, CRSwNP, immunodeficiency or its suspicion, non-steroidal anti-inflammatory drug exacerbated respiratory disease, and number of any diseases ≥2. CONCLUSIONS: Our study showed that comorbidities differ between pediatric and adult rhinosinusitis patients, as allergy, asthma and allergy, chronic otitis media, mental health disorders, and tonsils disease were significantly more prevalent among pediatric patients. Children and adults were equally treated with ESS. Notably, children underwent additional surgery on adenoids and tonsils more frequently. The effectiveness of ESS in multimorbid adults should be assessed at an individual level.

2.
J Int Adv Otol ; 20(1): 1-7, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38454281

RESUMEN

BACKGROUND: The clinical outcomes of cochlear implantation vary for several reasons. It is necessary to study the different electrodes and variables for further development. The aim of this study is to report the clinical outcomes of a new slim lateral wall electrode (SlimJ). METHODS: Data of 25 cochlear implantations in 23 patients with the SlimJ electrode were retrospectively collected. The insertion results were assessed by image fusion of the preoperative computed tomography (CT), magnetic resonance imaging (MRI), and postoperative cone-beam CT. The hearing outcomes were evaluated by the improvement of speech recognition in noise, measured preoperatively and at follow-up. Postoperative pure-tone thresholds were obtained in cases with preoperative functional low frequency hearing [PTA (0.125-0.5 kHz) ≤ 80 dB HL]. RESULTS: The preoperative mean speech reception threshold (SRT) was +0.6 dB signal-to-noise ratio (SNR) (SD ± 4.2 dB) and the postoperative -3.5 dB SNR (SD ± 2.3 dB). The improvements between the preoperative and postoperative SRT levels ranged from 0.0 to 15.1 dB, with a mean improvement of 4.2 dB (SD ± 3.6 dB). Residual hearing in low frequencies (mean PTA(125-500 Hz)) was preserved within 30 dB HL in 70% and within 15 dB HL in 40% of patients who had preoperatively functional low frequency hearing. Mean insertion depth angle (IDA) was 401° (SD ± 41°). We observed scalar translocations from scala tympani to scala vestibuli in 2 ears (9%). CONCLUSION: The relatively atraumatic insertion characteristics make the SlimJ array feasible for hearing preservation cochlear implantation. The hearing outcomes are comparable to those reported for other electrodes and devices.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Estudios Retrospectivos , Audición , Implantación Coclear/métodos , Audiometría de Tonos Puros , Resultado del Tratamiento
3.
Eur Arch Otorhinolaryngol ; 281(2): 701-710, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37505263

RESUMEN

PURPOSE: The opportunities for surgical training and practice in the operating room are in decline due to limited resources, increased efficiency demands, growing complexity of the cases, and concerns for patient safety. Virtual reality (VR) offers a novel opportunity to enhance surgical training and provide complementary three-dimensional experience that has been usually available in the operating room. Since VR allows viewing and manipulation of realistic 3D models, the VR environment could enhance anatomical and topographical knowledge, in particular. In this study, we explored whether incorporating VR anatomy training improves novices' performance during mastoidectomy over traditional methods. METHODS: Thirty medical students were randomized into two groups and taught mastoidectomy in a structured manner. One group utilized a VR temporal bone model during the training while the other group used more traditional materials such as anatomy books. After the training, all participants completed a mastoidectomy on a 3D-printed temporal bone model under expert supervision. Performance during the mastoidectomy was evaluated with multiple metrics and feedback regarding the two training methods was gathered from the participants. RESULTS: The VR training method was rated better by the participants, and they also needed less guidance during the mastoidectomy. There were no significant differences in operational time, the occurrence of injuries, self-assessment scores, and the surgical outcome between the two groups. CONCLUSION: Our results support the utilization of VR training in complete novices as it has higher trainee satisfaction and leads to at least as good results as the more traditional methods.


Asunto(s)
Otolaringología , Entrenamiento Simulado , Realidad Virtual , Humanos , Mastoidectomía/educación , Estudios Prospectivos , Otolaringología/educación , Entrenamiento Simulado/métodos , Competencia Clínica
4.
J Vis Exp ; (198)2023 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-37607083

RESUMEN

The extraction of the cochlea from a cadaver human temporal bone may be required for different studies of the inner ear. For histological evaluations, the inner ear must be extracted from the temporal bone to facilitate histologic processing; likewise, some micro-computed tomography devices are too small to accommodate the complete temporal bones; additionally, the image quality can be enhanced when the cochlea is isolated. The inner ear is located within the petrous part of the temporal bone. The inner ear can be divided into the osseous labyrinth or otic capsule and the membranous labyrinth inside the otic capsule. Furthermore, the inner ear can be divided into the vestibular system (the semicircular canals and the vestibule) and the cochlea. The appreciation of the location and orientation of the cochlea within the temporal bone is difficult, as it is embedded within bony structures and thus cannot be directly visualized. Nevertheless, there are distinct anatomical structures that can help guide the process to allow a reliable drill-out of the cochlea. The landmarks in the posterior parts of the cochlea are the facial nerve, semicircular canals, and the vestibule. In the middle, the inferior borders of the cochlea are identified by the round window and the basal turn of the cochlea. In the anterior border, one encounters the carotid artery; the landmark for the superior border is the genicular ganglion (GG) of the facial nerve. The medial structures are determined by the locations of the internal auditory canal, the superior semicircular canal, and the canal of the internal carotid artery. In this article, we present a method for extracting the cochlea reliably out of the temporal bone by drill-out while following several anatomical landmarks.


Asunto(s)
Cóclea , Vestíbulo del Laberinto , Humanos , Microtomografía por Rayos X , Cóclea/diagnóstico por imagen , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía , Cadáver
5.
Sci Rep ; 13(1): 10967, 2023 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-37414822

RESUMEN

The aim of this study was to understand the mastoid volume development in children who undergo cochlear implantation surgery. Cochlear implant (CI) database of our clinic (Kuopio University Hospital) was reviewed for computed tomography (CT) images of CI patients (age under 12 years at the time of implantation) with a minimum time interval of twelve months between their pre- and postoperative CT. Eight patients (nine ears) were found eligible for inclusion. Three linear measurements were taken by using picture archiving and communication systems (PACS) software and the volume of the MACS was measured with Seg 3D software. The mastoid volume increased on average 817.5 mm3 between the pre- and the postoperative imaging time point. The linear distances measured between anatomical points like the round window (RW)- bony ear canal (BEC), the RW-sigmoid sinus (SS), the BEC-SS, and the mastoid tip (MT)-superior semicircular canal (SSC) increased significantly with the age of the patient at both the pre-op and post-op time points. The linear measurements between key anatomical points and mastoid volume showed a positive linear correlation. The correlation between linear measurement and volume were significant between the MT-SSC (r = 0.706, p = 0.002), RW-SS (r = 0.646, p = 0.005) and RW-BEC (r = 0.646, p = 0.005). Based on our findings from the CI implanted patients and comparing it with the previous literature findings from non-CI implanted patients, we could say that the CI surgery seem to have no effect on the development of mastoid volume in children.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Niño , Implantación Coclear/métodos , Apófisis Mastoides/diagnóstico por imagen , Apófisis Mastoides/cirugía , Ventana Redonda/cirugía , Oído/cirugía
6.
Otol Neurotol ; 44(8): 786-790, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37464472

RESUMEN

OBJECTIVE: To compare the three-dimensional (3D) footswitch-operated robotic arm exoscope with the operating microscope (OM) in cochlear implant surgery. STUDY DESIGN: Matched case-control study. PATIENTS: Cochlear implantation was performed with the exoscope on unselected patients with normal temporal anatomy. The control group that underwent cochlear implantation with the OM was case matched with respect to age, anatomy, surgical technique, and type of anesthesia. INTERVENTIONS: Cochlear implantation performed with the 3D exoscope. MAIN OUTCOME MEASURES: Surgical time, occupation of the operation theater, surgical results, and user experience evaluated by a questionnaire. RESULTS: Eleven patients (13 ears) were successfully operated on with the exoscope. In the exoscope group, we observed one minor intraoperative complication, where the middle dura was exposed during mastoidectomy. Although no clear preference was evident for either device in the overall rating, the subdomain rating revealed that the exoscope's image quality was deemed inferior, especially at higher magnifications where pixelation became noticeable. The exoscope received higher scores for usability, particularly excelling in terms of surgeon's ergonomic and comfortability. There was a statistically significant difference in mean surgical time, 146 and 129 min for the exoscope and OM group, respectively. CONCLUSIONS: Cochlear implant surgery was found to be feasible with a 3D exoscope. However, there is a learning curve to overcome regarding handling and the different quality of the image. The exoscope provides better ergonomics for the surgeon.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Procedimientos Quirúrgicos Robotizados , Humanos , Estudios de Casos y Controles , Estudios de Factibilidad , Procedimientos Neuroquirúrgicos/métodos
7.
J Vis Exp ; (195)2023 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-37306464

RESUMEN

The developments in surgical techniques and cochlear implant (CI) electrode design have expanded the indications for CI treatment. Currently, patients with high-frequency hearing loss may benefit from CIs when low-frequency residual hearing can be preserved, as this enables combined electric-acoustic stimulation (EAS). The possible benefits of EAS include, for example, improved sound quality, music perception, and speech intelligibility in noise. The risks of inner ear trauma and a deterioration or even complete loss of residual hearing vary according to the surgical technique and the type of electrode array used. Short, lateral-wall electrodes with shallower angular insertion depths have demonstrated higher rates of hearing preservation than longer electrodes. The very slow insertion of the electrode array through the round window of the cochlea contributes to insertion atraumaticity and, thus, may lead to favorable hearing preservation results. However, residual hearing can be lost even after an atraumatic insertion. Electrocochleography (ECochG) can be used to monitor inner ear hair cell function during the insertion of the electrode. Several investigators have demonstrated that the ECochG responses during surgery may predict postoperative hearing preservation results. In a recent study, we correlated the patients' subjective hearing perception with simultaneously recorded intracochlear ECochG responses during the insertion. This is the first report evaluating the association between intraoperative ECochG responses and hearing perception in a subject undergoing cochlear implantation under local anesthesia without sedation. The combination of intraoperative ECochG responses with the patient's real-time feedback to sound stimuli has excellent sensitivity for the intraoperative monitoring of cochlear function. This paper presents a state-of-the-art method for the preservation of residual hearing during CI surgery. We describe this treatment procedure with the special consideration of performing the surgery under local anesthesia, which makes it feasible for monitoring the patient's hearing during the insertion of the electrode array.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Audición , Percepción Auditiva , Anestesia Local
8.
Otol Neurotol ; 44(4): 339-345, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36843083

RESUMEN

HYPOTHESIS: Micro-computed tomography (micro-CT) and cone-beam computed tomography (CBCT), in conjunction with the image fusion technique, may provide similar results for trauma assessment after cochlear implantation, with respect to the trauma evaluation in preclinical cochlear implant (CI) studies, as the histology. BACKGROUND: Before clinical use, novel cochlear implant (CI) designs are tested in temporal bone (TB) studies for usability and risk evaluation. The criterion standard for evaluating intracochlear insertion trauma and electrode location has historically been with histological samples. Progress of modern imaging technology has created alternatives to classic histology. This study compares the micro-CT and CBCT fusion images between histological samples in a preclinical CI study. METHODS: Fourteen freshly frozen TBs were inserted with a lateral wall research CI electrode. All TBs were scanned with CBCT preoperatively and postoperatively. After insertion, the TBs were prepared for micro-CT and histology. Twelve TBs underwent first a micro-CT and then the histological process. The CBCTs were used for image fusion, and all three different methods were used for intracochlear trauma evaluation. The results were compared between methods. RESULTS: There were 4 of 14 translocations detected with the fusion image method and 3 of 12 with the micro-CT and histology. When compared, the trauma grades converged and were not statistically significant. CONCLUSION: The trauma grading based on micro-CT is comparable to the histology. The image fusion technique based on CBCT is less accurate because it relies on an empirical assumption of the basal membrane localization, but it is clinically applicable.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Microtomografía por Rayos X , Implantes Cocleares/efectos adversos , Tomografía Computarizada de Haz Cónico/métodos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía , Cóclea/diagnóstico por imagen , Cóclea/cirugía
9.
Front Neurosci ; 16: 786939, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35733938

RESUMEN

Understanding speech is essential for adequate social interaction, and its functioning affects health, wellbeing, and quality of life (QoL). Untreated hearing loss (HL) is associated with reduced social activity, depression and cognitive decline. Severe and profound HL is routinely rehabilitated with cochlear implantation. The success of treatment is mostly assessed by performance-based outcome measures such as speech perception. The ultimate goal of cochlear implantation, however, is to improve the patient's QoL. Therefore, patient-reported outcomes measures (PROMs) would be clinically valuable as they assess subjective benefits and overall effectiveness of treatment. The aim of this study was to assess the patient-reported benefits of unilateral cochlear implantation in an unselected Finnish patient cohort of patients with bilateral HL. The study design was a prospective evaluation of 118 patients. The patient cohort was longitudinally followed up with repeated within-subject measurements preoperatively and at 6 and 12 months postoperatively. The main outcome measures were one performance-based speech-in-noise (SiN) test (Finnish Matrix Sentence Test), and two PROMs [Finnish versions of the Speech, Spatial, Qualities of Hearing questionnaire (SSQ) and the Nijmegen Cochlear Implant Questionnaire (NCIQ)]. The results showed significant average improvements in SiN scores, from +0.8 dB signal-to-noise ratio (SNR) preoperatively to -3.7 and -3.8 dB SNR at 6 and12 month follow-up, respectively. Significant improvements were also found for SSQ and NCIQ scores in all subdomains from the preoperative state to 6 and 12 months after first fitting. No clinically significant improvements were observed in any of the outcome measures between 6 and 12 months. Preoperatively, poor SiN scores were associated with low scoring in several subdomains of the SSQ and NCIQ. Poor preoperative SiN scores and low PROMs scoring were significantly associated with larger postoperative improvements. No significant association was found between SiN scores and PROMs postoperatively. This study demonstrates significant benefits of cochlear implantation in the performance-based and patient-reported outcomes in an unselected patient sample. The lack of association between performance and PROMs scores postoperatively suggests that both capture unique aspects of benefit, highlighting the need to clinically implement PROMs in addition to performance-based measures for a more holistic assessment of treatment benefit.

10.
Otol Neurotol ; 43(5): e540-e547, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35184073

RESUMEN

OBJECTIVE: Intraoperative electrocochleography (ECochG) has been proposed for cochlear monitoring to minimize trauma during the insertion of the electrode of a cochlear implant (CI). CI surgery is normally performed under general anesthesia, which is why intraoperative ECochG measurements have never been validated against the patient's subjective sound perception. The main objectives of this study were to investigate the feasibility of cochlear monitoring based on the patients hearing and to validate it against intraoperative ECochG measurements during CI surgery under local anesthesia. STUDY DESIGN: Prospective case series study. SETTING: Tertiary referral center. PATIENTS: Patients eligible for cochlear implantation with residual hearing (pure-tone threshold averages [PTA] 2501000 Hz ≤ 75 dB HL). Additionally, patients should be able to hear ECochG stimuli at 250, 500, or 1000 Hz at less than or equal to 100 dB (HL). INTERVENTIONS: Cochlear implantation under local anesthesia without conscious sedation. Intraoperative ECochG monitoring. MAIN OUTCOME MEASURES: The development of ECochG amplitudes and the patients' subjective perception to the sound stimuli. RESULTS: In all patients, monitoring based on their subjective sound perception was feasible, whereas, reliable ECochG responses could be measured in seven patients. Sixty percent of the registered declines in ECochG amplitude were associated with a concomitant attenuation of the subjectively perceived sound. CONCLUSIONS: The developments in the ECochG responses matched well with the changes of the sound stimulus perceived by the patients, which supports the applicability of ECochG for preventing insertion trauma. Monitoring of the patients subjective hearing appears to be more reliable than ECochG but requires surgery under local anesthesia without conscious sedation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Anestesia Local , Audiometría de Respuesta Evocada , Audición , Humanos , Percepción
11.
Eur Arch Otorhinolaryngol ; 279(7): 3379-3385, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34487218

RESUMEN

PURPOSE: To report the outcomes and the patients' subjective experience of cochlear implantation (CI) performed under local anesthesia (LA). To describe a new form of intraoperative cochlear monitoring based on the patients subjective sound perception during CI. METHODS: In this retrospective case-cohort study, 117 patients underwent CI under LA with (n = 58) or without conscious sedation (n = 59). Included were primarily elderly patients with elevated risks for general anesthesia and recently patients with residual hearing eligible for electro-acoustic stimulation (EAS) (n = 27), in whom hearing could be monitored during the electrode insertion. A 500 Hz test tone was presented and the patient reported  of subjective changes in loudness, leading to a modification of the insertion. A questionnaire was sent to all patients in which they assessed their subjective experience. RESULTS: All patients were successfully operated under LA without the need to intraoperatively convert to general anesthesia. 90% of the patients reported that the surgery was a positive experience. The vast majority, 90% of patients were satisfied with the overall treatment and with intraoperative pain management and 84% of the patients would opt for local anesthesia again. Cochlear monitoring by the patients' subjective sound perception enabled for atraumatic insertions as all EAS patients could hear the test tone up to the end of the surgery. CONCLUSIONS: CI under LA was well tolerated and recommended by the vast majority of patients. In addition, it offers the possibility to monitor the patients' hearing during the electrode insertion, which may help to prevent insertion trauma.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Anciano , Anestesia Local , Umbral Auditivo , Estudios de Cohortes , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
12.
Ear Hear ; 43(1): 220-233, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34260435

RESUMEN

OBJECTIVES: Early hearing aid (HA) fitting and cochlear implants (CIs) aim to reduce the effects of hearing loss (HL) on spoken language development. The goals of this study were (1) to examine spoken language skills of children with bilateral HAs and children with bilateral CIs; (2) to compare their language skills to the age-norms of peers with normal hearing (NH); and (3) to investigate factors associated with spoken language outcomes. DESIGN: Spoken language results of 56 Finnish children with HL were obtained from a nationwide prospective multicenter study. Children with HL comprised two groups: children with mild-to-severe HL who used bilateral HAs (BiHA group, n = 28) and children with profound HL who used bilateral CIs (BiCI group, n = 28). Children's spoken language comprehension, expressive and receptive vocabulary, and phonological skills were compared with normative values of children with NH at the age of three years. Odds ratio (OR) was calculated to compare proportions of children below age-norms in BiHA and BiCI groups. Factors associated with spoken language outcomes were modeled with analysis of covariance. RESULTS: At the age of 3 years, 50%-96% of children with HL performed 1 SD or more below the mean of the normative sample of age-peers with NH in spoken language skills, depending on the language domain. Receptive vocabulary and phonological skills were the most vulnerable language domains. In receptive vocabulary, 82% of the children in the BiHA group and 50% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 4.4 times more likely to have poorer receptive vocabulary than the BiCI group. In phonological skills, 96% of children in the BiHA group and 60% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 18.0 times more likely to have poorer phonological skills than the BiCI group. The analysis of covariance models showed that unaided pure-tone average, PTA0.5-4 kHz, had a significant effect on spoken language comprehension in the BiHA group. For the BiCI group, age at HL diagnosis and age at CI activation had a significant effect on expressive vocabulary. High maternal level of education had a significant effect on language comprehension and expressive vocabulary and female gender on phonological skills. CONCLUSIONS: At the age of 3 years, especially receptive vocabulary and phonological skills caused difficulties for children with HL showing also considerable individual variation. Children with bilateral HAs seemed to be more likely to have poorer receptive vocabulary and phonological skills than children with bilateral CIs. A variety of factors was associated with outcomes in both groups. Close monitoring of spoken language skills of children with HL is important for ensuring similar opportunities for all children with HL and timely intervention, when needed.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Audífonos , Pérdida Auditiva , Niño , Preescolar , Implantación Coclear/métodos , Sordera/cirugía , Femenino , Humanos , Desarrollo del Lenguaje , Masculino , Estudios Prospectivos , Vocabulario
13.
Eur Arch Otorhinolaryngol ; 279(9): 4303-4312, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34837519

RESUMEN

PURPOSE: There is only limited data on the application of virtual reality (VR) for the evaluation of temporal bone anatomy. The aim of the present study was to compare the VR environment to traditional cross-sectional viewing of computed tomography images in a simulated preoperative planning setting in novice and expert surgeons. METHODS: A novice (n = 5) and an expert group (n = 5), based on their otosurgery experience, were created. The participants were asked to identify 24 anatomical landmarks, perform 11 distance measurements between surgically relevant anatomical structures and 10 fiducial markers on five cadaver temporal bones in both VR environment and cross-sectional viewings in PACS interface. The data on performance time and user-experience (i.e., subjective validation) were collected. RESULTS: The novice group made significantly more errors (p < 0.001) and with significantly longer performance time (p = 0.001) in cross-sectional viewing than the expert group. In the VR environment, there was no significant differences (errors and time) between the groups. The performance of novices improved faster in the VR. The novices showed significantly faster task performance (p = 0.003) and a trend towards fewer errors (p = 0.054) in VR compared to cross-sectional viewing. No such difference between the methods were observed in the expert group. The mean overall scores of user-experience were significantly higher for VR than cross-sectional viewing in both groups (p < 0.001). CONCLUSION: In the VR environment, novices performed the anatomical evaluation of temporal bone faster and with fewer errors than in the traditional cross-sectional viewing, which supports its efficiency for the evaluation of complex anatomy.


Asunto(s)
Competencia Clínica , Realidad Virtual , Simulación por Computador , Estudios Transversales , Humanos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía , Interfaz Usuario-Computador
14.
J Clin Med ; 10(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34441961

RESUMEN

BACKGROUND: A large number of different speech-in-noise (SIN) tests are available for testing cochlear implant (CI) recipients, but few studies have compared the different tests in the same patient population to assess how well their results correlate. METHODS: A clinically representative group of 80 CI users conducted the Finnish versions of the matrix sentence test, the simplified matrix sentence test, and the digit triplet test. The results were analyzed for correlations between the different tests and for differences among the participants, including age and device modality. RESULTS: Strong and statistically significant correlations were observed between all of the tests. No floor or ceiling effects were observed with any of the tests when using the adaptive test procedure. Age or the length of device use showed no correlation to SIN perception, but bilateral CI users showed slightly better results in comparison to unilateral or bimodal users. CONCLUSIONS: Three SIN tests that differ in length and complexity of the test material provided comparable results in a diverse CI user group.

15.
J Otol ; 16(3): 150-157, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34220984

RESUMEN

PURPOSE: An important outcome measure of patient care is the impact on the patient's health-related quality of life (HRQoL). Current ear-specific HRQoL instruments are designed for one diagnosis and emphasize different subdivisions such as symptoms, hearing problems, psychosocial impact, and the need for care. The optimal length of the recall period has not been studied. For these reasons, a new survey is needed that would cover most chronic ear diseases. METHODS: A preliminary 24-item survey (EOS-24) was created. Untreated adult patients (included n = 186) with one of seven different chronic otologic conditions from all university hospitals in Finland were recruited to respond to EOS-24 and the 15D general HRQoL instrument. The recruiting otologists evaluated the severity of the disease and the disability caused by it. A control group was recruited. Based on the patients' responses in different diagnosis groups, the items were reduced according to pre-defined criteria. The resulting survey was validated using a thorough statistical analysis. RESULTS: The relevance and necessity of the original 24 items were thoroughly investigated, leading to the exclusion of 8 items and the modification of 1. The remaining 16 items were well-balanced between subdivisions and were useful in all seven diagnosis groups, thus constituting the final instrument, EOS-16. The most suitable recall period was three months. CONCLUSIONS: EOS-16 has been created according to the HRQoL survey guidelines with a versatile nationwide patient population. The survey has been validated and can be used for a wide range of chronic ear diseases as a HRQoL instrument.

16.
J Clin Med ; 10(11)2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34071662

RESUMEN

Bilateral cochlear implantation is increasing worldwide. In adults, bilateral cochlear implants (BICI) are often performed sequentially with a time delay between the first (CI1) and the second (CI2) implant. The benefits of BICI have been reported for well over a decade. This study aimed at investigating these benefits for a consecutive sample of adult patients. Improvements in speech-in-noise recognition after CI2 were followed up longitudinally for 12 months with the internationally comparable Finnish matrix sentence test. The test scores were statistically significantly better for BICI than for either CI alone in all assessments during the 12-month period. At the end of the follow-up period, the bilateral benefit for co-located speech and noise was 1.4 dB over CI1 and 1.7 dB over CI2, and when the noise was moved from the front to 90 degrees on the side, spatial release from masking amounted to an improvement of 2.5 dB in signal-to-noise ratio. To assess subjective improvements in hearing and in quality of life, two questionnaires were used. Both questionnaires revealed statistically significant improvements due to CI2 and BICI. The association between speech recognition in noise and background factors (duration of hearing loss/deafness, time between implants) or subjective improvements was markedly smaller than what has been previously reported on sequential BICI in adults. Despite the relatively heterogeneous sample, BICI improved hearing and quality of life.

17.
Eur Arch Otorhinolaryngol ; 278(8): 2795-2806, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32964264

RESUMEN

PURPOSE: Consumer-grade virtual reality (VR) has recently enabled various medical applications, but more evidence supporting their validity is needed. We investigated the accuracy of simulated surgical planning in a VR environment (VR) with temporal bones and compared it to conventional cross-sectional image viewing in picture archiving and communication system (PACS) interface. METHODS: Five experienced otologic surgeons measured significant anatomic structures and fiducials on five fresh-frozen cadaveric temporal bones in VR and cross-sectional viewing. Primary image data were acquired by computed tomography. In total, 275 anatomical landmark measurements and 250 measurements of the distance between fiducials were obtained with both methods. Distance measurements between the fiducials were confirmed by physical measurement obtained by Vernier caliper. The experts evaluated the subjective validity of both methods on a 5-point Likert scale qualitative survey. RESULTS: A strong correlation based on intraclass coefficient was found between the methods on both the anatomical (r > 0.900) and fiducial measurements (r > 0.916). Two-tailed paired t-test and Bland-Altman plots demonstrated high equivalences between the VR and cross-sectional viewing with mean differences of 1.9% (p = 0.396) and 0.472 mm (p = 0.065) for anatomical and fiducial measurements, respectively. Gross measurement errors due to the misidentification of fiducials occurred more frequently in the cross-sectional viewing. The mean face and content validity rating for VR were significantly better compared to cross-sectional viewing (total mean score 4.11 vs 3.39, p < 0.001). CONCLUSION: Our study supports good accuracy and reliability of VR environment for simulated surgical planning in temporal bones compared to conventional cross-sectional visualization.


Asunto(s)
Realidad Virtual , Estudios Transversales , Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía
18.
Int J Audiol ; 60(3): 210-219, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32964762

RESUMEN

OBJECTIVE: Speech-in-noise tests are widely used in hearing diagnostics but typically without reverberation, although reverberation is an inextricable part of everyday listening conditions. To support the development of more real-life-like test paradigms, the objective of this study was to explore how spatially reproduced reverberation affects speech recognition thresholds in normal-hearing and hearing-impaired listeners. DESIGN: Thresholds were measured with a Finnish speech-in-noise test without reverberation and with two test conditions with reverberation times of ∼0.9 and 1.8 s. Reverberant conditions were produced with a multichannel auralisation technique not used before in this context. STUDY SAMPLE: Thirty-four normal-hearing and 14 hearing-impaired listeners participated in this study. Five people were tested with and without hearing aids. RESULTS: No significant differences between test conditions were found for the normal-hearing listeners. Results for the hearing-impaired listeners indicated better performance for the 0.9 s reverberation time compared to the reference and the 1.8 s conditions. Benefit from hearing aid use varied between individuals; for one person, an advantage was observed only with reverberation. CONCLUSIONS: Auralisations may offer information on speech recognition performance that is not obtained with a test without reverberation. However, more complex stimuli and/or higher signal-to-noise ratios should be used in the future.


Asunto(s)
Audífonos , Percepción del Habla , Audición , Humanos , Ruido/efectos adversos , Habla
19.
Front Neurosci ; 14: 640, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32694976

RESUMEN

BACKGROUND: Distinct tissue types are differentiated based on the surgeon's knowledge and subjective visible information, typically assisted with white-light intraoperative imaging systems. Narrow-band imaging (NBI) assists in tissue identification and enables automated classifiers, but many anatomical details moderate computational predictions and cause bias. In particular, tissues' light-source-dependent optical characteristics, anatomical location, and potentially hazardous microstructural changes such as peeling have been overlooked in previous literature. METHODS: Narrow-band images of five (n = 5) facial nerves (FNs) and internal carotid arteries (ICAs) were captured from freshly frozen temporal bones. The FNs were split into intracranial and intratemporal samples, and ICAs' adventitia was peeled from the distal end. Three-dimensional (3D) spectral data were captured by a custom-built liquid crystal tunable filter (LCTF) spectral imaging (SI) system. We investigated the normal variance between the samples and utilized descriptive and machine learning analysis on the image stack hypercubes. RESULTS: Reflectance between intact and peeled arteries in lower-wavelength domains between 400 and 576 nm was significantly different (p < 0.05). Proximal FN could be differentiated from distal FN in a higher range, 490-720 nm (p < 0.001). ICA with intact tunica differed from proximal FN nearly thorough the VIS range, 412-592 nm (p < 0.001) and 664-720 nm (p < 0.05) as did its distal counterpart, 422-720 nm (p < 0.001). The availed U-Net algorithm classified 90.93% of the pixels correctly in comparison to tissue margins delineated by a specialist. CONCLUSION: Selective NBI represents a promising method for assisting tissue identification and computational segmentation of surgical microanatomy. Further multidisciplinary research is required for its clinical applications and intraoperative integration.

20.
Int J Audiol ; 59(10): 753-762, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32338546

RESUMEN

Objectives: To assess are there learning-related improvements in the speech reception thresholds (SRTs) for the Finnish matrix sentence test (FMST) and the Finnish digit triplet test (FDTT) in repeated use over 12 months.Design: Test sessions were scheduled at 0, 1, 3, 6 and 12 months, and each session included five FMST measurements and four FDTT measurements. The within-session and inter-session improvements in SRTs were analysed with a linear mixed model.Study sample: Fifteen young normal-hearing participants.Results: Statistically significant mean improvements of 2.0 dB SNR and 1.2 dB SNR were detected for the FMST and the FDTT, respectively, over the 12-month follow-up period. For the FMST, majority of the improvement occurred during the first two test sessions. For the FDTT, statistically significant differences were detected only in comparison to the first test session and to the first test measurement of every session over the 12-month follow-up.Conclusions: Repeated use of the FMST led to significant learning-related improvements, but the improvements appeared to plateau by the third test session. For the FDTT, the overall improvements were smaller, but a significant within-session difference between the first and consecutive FDTT measurements persisted throughout the test sessions.


Asunto(s)
Ruido , Percepción del Habla , Finlandia , Humanos , Reproducibilidad de los Resultados , Prueba del Umbral de Recepción del Habla
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...